| Dextrose Injection I.P. (5% W/V) | |
| Test Description Identification pH Heavy metals Bacterial Endotoxin test 5-Hydroxymethylfurfural & related substances Sterility Extractable volume Particulate Matter Assay |
Specification |
| Dextrose Injection B.P. (5% W/V) | |
| Test Description Identification Acidity Heavy metals Bacterial Endotoxin test 5-Hydroxymethylfurfural & related substances Sterility Extractable volume Particulate Contamination Assay |
Specification |
| Sodium Chloride Injection I.P. (0.9% W/V) | |
| Test Description Identification pH Heavy metals Extractable volume Particulate matter Sterility Bacterial Endotoxin test Assay |
Specification Clear, colourless liquid Should comply IP1996 4.5 to 7.0 Not more than 0.3ppm 500 to 510ml Should comply IP1996 Should comply IP1996 Not more than 0.25 EU/ml Not less than 0.85% and not be more than 0.95% |
| Sodium Chloride Injection B.P. (0.9% W/V) | |
| Test Characteristics Identification Particulate Contamination Test of sterility Bacterial Endotoxin Test Assay |
Specification Clear, colourless liquid Should comply BP1999 Should comply BP1999 Should comply BP1999 Should comply BP1999 (Endotoxin Lmit is not more than 0.25EU/ml) Not less than 95% and not more than 105% w/v of Lable of sodium chloride |
| Sodium Chloride 0.9% W/V & Dextrose 5% W/V Injection I.P. | |
| Test Description Identification pH Bacterial Endotoxin Test 5- Hydroxymethylfurfural & related substances Sterility Extractable volume Particulate Matter Assay |
Specification Clear, colourless liquid Should comply IP1996 Between 3.5 & 6.5 Not more than 10EU /gm of dextrose Extinction should not more than 0.25 Should comply IP1996 Between -500& 510ml Should comply IP1996 Not less than 95% and not more than 105% of sodium chloride & Dextrose |
| Sodium Chloride 0.9% W/V & Dextrose 5% W/V Injection B.P. | |
| Test Characteristics Identification Acidity Bacterial Endotoxin Test 5- Hydroxymethylfurfural & related substances Sterility Extractable volume Particulate Contamination Assay |
Specification Clear, colourless liquid Should comply BP1999 pH Between 3.5 & 6.5 Not more than 0.25 EU /gm Extinction should not more than 0.25 Should comply BP1999 Between -500& 510 Should comply BP1999 Not less than 95% and not more than 105% of sodium chloride & Dextrose |
| Compound Sodium Lactate Injection I.P. | |
| Test Description Identification pH Extractable volume Particulate Matter Sterility Bacterial Endotoxin Test Assay Total Chloride Calcium Chloride Lactic acid Total Sodium Total Potassium |
Specification Clear, colourless liquid Should comply IP1996 Between 5.0 & 7.0 Between -500& 510ml Should comply IP1996 Should comply IP1996 Not more than 0.5 Eu/ml 0.37%w/v to 0.42%w/v 0.025%w/v to 0.029%w/v 0.23%w/v to 0.28%w/v 0.27%w/v to 0.32%w/v 0.019%w/v to 0.022%w/v |
|
"He
who has health,